Prog_bar doesn't seem to work with my A600. How can I fix this?
Get the newest version from the downloads page. Versions before v1.04 used a structure which was not word aligned and this caused Prog_bar to crash on any 68000 based machine. I programmed Prog_Bar using a 68030 equipped A1200 which can quite happily deal with 16 bit accesses to odd addresses, so this problem did not appear during development.
Many thanks to Oliver Roberts who discovered, identified and reported this problem.